1. Scope
This specification covers the characteristics of the following SAW Duplexer used for the cordless phones:
2. Package
Type: ACTF46-49/46.79-49.83/W2
3. Characteristics
3.1 Maximum Rating Rating
Operable Temperature Range Storage Temperature Range DC Voltage (between any terminals) Source power PS TA Tstg VDC
Value
-10 to +65 -40 to +85 0 15
Unit
C C V dBm
In keeping with our ongoing policy of product evolvement and improvement, the above specification is subject to change without notice.
ISO9001: 2000 Registered - Registration number 6830/2
For quotations or further information please contact us at: 3 The Business Centre, Molly Millars Lane, Wokingham, Berks, RG41 2EY, UK
Issue : 1 C1 Date : SEPT 04
http://www.actcrystals.com
Tel : +44 118 979 1238 Fax : +44 118 979 1283 Email: info@actcrystals.com
3.2 Electrical Characteristics Characteristics of channel 46: Reference temperature: TA=25C Source impedance: ZS=50 Load impedance: ZL =50 Item Freq Nominal frequency fN Insertion attenuation 46.61~46.97MHz 20.00~43.50MHz Attenuation 49.67~49.99MHz 49.99~80.00MHz Temperature coefficient Characteristics of channel 49: Reference temperature: TA=25C Source impedance: ZS=50 Load impedance: ZL =50 Item Freq Nominal frequency fN Insertion attenuation 49.67~49.99MHz 20.00~46.61MHz Attenuation 46.61~46.97MHz 53.50~80.00MHz Temperature coefficient Isolation between 46 and 49: Reference temperature: TA=25C Source impedance: ZS=50 Load impedance: ZL=50 Item Attenuation Freq 46.61~46.97MHz 49.67~49.99MHz min. 40.0 40.0 typ. 48.0 45.0 max. Units dB min. typ. 49.83 3.5 32.0 37.0 32.0 36.0 47.0 36.0 -72 max. 5.0 Units MHz dB dB ppm/k min. typ. 46.79 3.5 32.0 37.0 32.0 36.0 47.0 36.0 -72 max. 5.0 Units MHz dB dB ppm/k
In keeping with our ongoing policy of product evolvement and improvement, the above specification is subject to change without notice.
ISO9001: 2000 Registered - Registration number 6830/2
For quotations or further information please contact us at: 3 The Business Centre, Molly Millars Lane, Wokingham, Berks, RG41 2EY, UK
Issue : 1 C1 Date : SEPT 04
http://www.actcrystals.com
Tel : +44 118 979 1238 Fax : +44 118 979 1283 Email: info@actcrystals.com
3.3 Environmental Performance Characteristics Item Test Condition High temperature test
70C 16H
Allowable change of absolute Level at centre frequency (dB) < 1.0 < 1.0 < 1.0 < 1.0 < 1.0 More then 95% of total Area of the pins should be covered with solder
Low temperature test
-25C 2H
Humidity test
40C 90-95% 100H
Thermal cycle
-25C==25C==70C 3 cycles 30min. 5min. 30min.
Solder temperature test
Sold temp.260C for 10 sec.
Soldering
Immerse the pins melt solder At 260C+5/-0C for 5 sec.
3.4 Mechanical Test Item Test Condition Vibration test
Frequency 10~55Hz amplitude 1.5mm 3 directions 2 H each
Allowable change of absolute Level at centre frequency (dB) <1.0 <1.0 <1.0 <1.0
Drop test
On maple plate from 1 m high 3 times
Lead pull test
Pull with 1 kg force for 30 seconds
Lead bend test
90o bending with 500g weigh 2 times
In keeping with our ongoing policy of product evolvement and improvement, the above specification is subject to change without notice.
ISO9001: 2000 Registered - Registration number 6830/2
For quotations or further information please contact us at: 3 The Business Centre, Molly Millars Lane, Wokingham, Berks, RG41 2EY, UK
Issue : 1 C1 Date : SEPT 04
http://www.actcrystals.com
Tel : +44 118 979 1238 Fax : +44 118 979 1283 Email: info@actcrystals.com
4. Frequency Response
Transfer function channel 46:
In keeping with our ongoing policy of product evolvement and improvement, the above specification is subject to change without notice.
ISO9001: 2000 Registered - Registration number 6830/2
For quotations or further information please contact us at: 3 The Business Centre, Molly Millars Lane, Wokingham, Berks, RG41 2EY, UK
Issue : 1 C1 Date : SEPT 04
http://www.actcrystals.com
Tel : +44 118 979 1238 Fax : +44 118 979 1283 Email: info@actcrystals.com
Transfer function channel 46 (pass band):
Transfer function channel 49:
In keeping with our ongoing policy of product evolvement and improvement, the above specification is subject to change without notice.
ISO9001: 2000 Registered - Registration number 6830/2
For quotations or further information please contact us at: 3 The Business Centre, Molly Millars Lane, Wokingham, Berks, RG41 2EY, UK
Issue : 1 C1 Date : SEPT 04
http://www.actcrystals.com
Tel : +44 118 979 1238 Fax : +44 118 979 1283 Email: info@actcrystals.com
Transfer function channel 49 (pass band):
Isolation between 46 and 49:
In keeping with our ongoing policy of product evolvement and improvement, the above specification is subject to change without notice.
ISO9001: 2000 Registered - Registration number 6830/2
For quotations or further information please contact us at: 3 The Business Centre, Molly Millars Lane, Wokingham, Berks, RG41 2EY, UK
Issue : 1 C1 Date : SEPT 04
http://www.actcrystals.com
Tel : +44 118 979 1238 Fax : +44 118 979 1283 Email: info@actcrystals.com
iCAUTION: Electrostatic Sensitive Device. Observe precautions for handling!
1.
Unless noted otherwise, all measurements are made with the filter installed in the specified test fixture that is connected to a 50 test system with VSWR1.2:1. The test fixture L and C are adjusted for minimum insertion loss at the filter centre frequency, fC. Note that insertion loss, bandwidth, and passband shape are dependent on the impedance matching component values and quality.
2. 3.
Unless noted otherwise, specifications apply over the entire specified operating temperature range. The specifications of this device are based on the test circuit shown above and subject to change or obsolescence without notice.
4.
All equipment designs utilizing this product must be approved by the appropriate government agency prior to manufacture or sale.
5.
Our liability is only assumed for the Surface Acoustic Wave (SAW) component(s) per se, not for applications, processes and circuits implemented within components or assemblies.
In keeping with our ongoing policy of product evolvement and improvement, the above specification is subject to change without notice.
ISO9001: 2000 Registered - Registration number 6830/2
For quotations or further information please contact us at: 3 The Business Centre, Molly Millars Lane, Wokingham, Berks, RG41 2EY, UK
Issue : 1 C1 Date : SEPT 04
http://www.actcrystals.com


▲Up To Search▲   

 
Price & Availability of ACTF464679W2

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X